Dell Computer Configuration Toolkit : Les codes erreur !

Vous connaissez certainement l’outil « CCTK » de Dell ! Le Dell Computer Configuration Toolkit permet de configurer les BIOS des machines Dell de facon relativement simplet et automatisable.

Cet outils et très bavard et nous founir de nombeux codes erreurs pour le debugging.

Retrouvez ci dessous la liste des codes erreurs remontés par l’outils :

0 Success
1 Attempt to read write-only parameter ‘%s’
2 Password cannot exceed 16 characters
3 A BMC was either not detected or is not supported
4 This username is already in use Enter a unique username
5 Access mode not supported
6 Cannot return number of requested data bytes
7 User ID 1 cannot be assigned a username
8 Cannot execute duplicated request
9 There was an error clearing the SEL
10 Clear SEL cannot be accompanied with any other option
11 racreset cannot be accompanied with any other option
12 Cannot execute command Command, or request parameter(s), not supported in present state
13 Command not supported on given channel
14 The community string may only contain printable ASCII characters
15 Destination unavailable Cannot deliver request to selected destination
16 Cannot execute command Insufficient privilege level
17 Command illegal for specified sensor or record type
18 Invalid commstring value
19 Hardware subsystem error Invalid data field in Request
20 Invalid destination IP address
21 The GUID is invalid
22 Invalid gateway
23 Invalid hostname
24 Invalid IP address
25 Invalid DNS IP address
26 Invalid sub net mask
27 Invalid value for PEF PEF value should be between 1 and 16
28 Reservation Canceled or Invalid Reservation ID
29 Invalid Time to live value
30 Invalid VLANID value
31 Invalid Command Used to indicate an unrecognized or unsupported command
32 Command invalid for given LUN
33 Load defaults cannot be accompanied with any other option
34 There was an error loading the defaults
35 Node Busy Command could not be processed because command processing resources are temporarily unavailable
36 Out of space Command could not be completed because of a lack of storage space required to execute the given command operation
37 This parameter is not supported
38 Parameter out of range One or more parameters in the data field of the Request are out of range
39 The password may only contain printable ASCII characters
40 Password test failed
41 Requested data length invalid
42 Requested data field length limit exceeded
43 Requested Sensor, data, or record not present
44 Request data truncated
45 Command response could not be provided
46 Command response could not be provided BMC initialization or initialization agent in progress
47 Command response could not be provided Device in firmware update mode
48 Command response could not be provided SDR Repository in update mode
49 Cannot execute command, SEL erase in progress
50 Attempt to set the ‘set in progress’ value when not in the ‘set in complete’ state
51 The SOL character ‘accumulate interval’ is invalid
52 The SOL character ‘send threshold’ is invalid
53 The SOL ‘retry interval’ is invalid
54 Command completed successfully
55 Timeout while processing command Response unavailable
56 Unspecified error
57 The password may only contain printable ASCII characters
58 Username cannot exceed 16 characters
59 Invalid VLANID value Enter in ‘dddd’ format
60 Attempt to write read-only parameter ‘%s’
61 BMC is busy
62 Response data did not return successfully
63 BMC time out error
64 Invalid Configuration Option
65 Cannot execute commandParameter is illegal because command sub-function has been disabled or is unavailable
66 Option ‘%s’ requires an argument
67 The asset tag for this system is not available
68 The asset tag cannot be more than 10 characters long
69 The required BIOS interfaces cannot be found on this system
70 The BIOS version information is not available
71 There is not enough free system memory to complete the BIOS update
72 The BIOS update file version is a different version class (A00, X00) than the current system BIOS Use the –force option to use this BIOS image
73 The BIOS update file version is older than the current system bios Use the –force option to use this BIOS image
74 The BIOS update file version is identical to the current system bios Use the –force option to use this BIOS image
75 The sequence list must be a comma-separated numerical list of valid unique boot device numbers (ex: 2, 1, 3)
76 The sequence list must be a comma-separated list of valid unique device names (ex: nicemb
77 There was an error setting the sequence
78 The list is not formatted correctly See the help for more details
79 The size of returned buffer is larger than the size of allocated buffer
80 There was a problem getting the state byte
81 The state byte is not available on this system
82 There was a problem setting the state byte
83 The state byte must be a value between 0 and 255 decimal
84 The CPU information is not available
85 The dependent option ‘%s’ required for this subcommand is missing in the command line
86 Duplicate sub command ‘%s’ has been entered
87 The script file does contain not a valid DTK environment script signature (%s)
88 The format of the environment variable is incorrect
89 The –envar/-s option can only be used for a single option
90 The –envar/-s option can only be used for report operations
91 The individual sub commands should be specified for the -s option
92 Getting external serial connector settings failed
93 Setting external serial connector settings failed
94 There was an error opening the file %s
95 File ‘%s’ does not have write permission
96 The file contains invalid option ‘%s’
97 The replication information does not match for this system
98 There can only be one section in the input file
99 Bad ini file, the section [%s] cannot be found
100 The format of the bios image file is incorrect
101 Report operations and set operations must be separate
102 Help is not available for the option ‘%s’
103 The -x (–hex) option can only be used with -b or -r
104 Input file ‘%s’ not found
105 Input file ‘%s’ cannot be read
106 Invalid argument for option ‘%s’
107 Function table lookup error
108 The machine ID was not found in the file ‘%s’
109 The system memory information is not available
110 Mode can only be used with the –pci option
111 The device name or index must be present in the boot order
112 The output file ‘%s’ could not be opened Please make sure the path exists and the media is not write protected
113 Could not write to output file, disk may be full
114 The current password must be supplied with a new password using –valsyspwd
115 The current password must be supplied with a new password using –valsetuppwd
116 The current password can only be supplied when setting a new password
117 Actions are not allowed for this filter Only alerts are allowed
118 There was an error getting the option ‘%s’
119 The option ‘%s’ is not available or cannot be configured through software
120 There was an error setting the option ‘%s’
121 The -n (–namefile) option can only be used with –pci
122 The password may only contain alphanumeric characters
123 The BIOS passwords have been disabled via jumper
124 The password length must be between 1 and 32
125 This password is locked and can only be unlocked by the admin user
126 There was an error setting the password
127 The LCD string length must be between 1 and %s
128 The LCD string may only contain alphanumeric characters
129 There was an error setting the LCD string
130 The second channel can only be set if the RAID controller is set to RAID
131 The set operation, ‘%s’, requires sub commands
132 The service tag for this system is not available
133 The system ID value is not available
134 The system information string is not available
135 A system error has occured
136 Usage error
137 The uuid information is not present on this system
138 The manufacturing/first-power-on date information is not present on this system
139 Version cannot be accompanied with any other option
140 The self-identify blinker timer should be set to 0
141 Encrypt key is too long142
143 Parameter has been temporarily disabled due to a dependancy on other settings
144 The old password supplied is incorrect The new password will not be set
145 Cannot stat /etc/omregcfg file
146 Getting nicselection settings failed
147 HAPI Driver Load Error
148 Filter action power reduction is only supported for the system power warn/fail filters
149 TPM Clear settings requires setup password
150 There is currently no TPM Clear request pending
151 Password is not required for retrieving the TPM options
152 Setup password is required for setting the TPM options
153 Invalid Password override
154 Invalid TPM set option
155 There was an error setting the TPM option
156 There is no setup password installed on this system
157 The setup password supplied is incorrect Please try again
158 Profile should be custom for setting cpupowermode, memorypowermode and fanmode
159 There was an error setting the Power Option
160 The power cap value entered is out of range Please try again
161 The power cap value entered must be between 0 to 100 if unit is percent
162 Invalid IPv6 address The IPv6 address cannot be link-local or multicast
163 Invalid IPv6 address The IPv6 address specified has incorrect address format
164 Invalid IPv6 address The gateway address specified has incorrect address format
165 Invalid IPv6 address The Primary DNS server address specified has incorrect address format
166 Invalid IPv6 address The Secondary DNS server address specified has incorrect address format
167 Invalid IPv6 address The gateway address specified is invalid
168 Invalid configuration Attempting to apply IPv6 configuration on a non supported platform
169 Invalid IPv6 configuration Attempt to set DNS server address manually while DNS address source is set to auto
170 Invalid IPv6 configuration Attempt to set IPv6 address manually while IPv6 address source is set to auto
171 Invalid IPv6 configuration Attempting to apply IPv6 configuration without loading IPv6 stack
172 Invalid IPv4 configuration Attempting to apply IPv4 configuration with IPv4 disabled
173 Invalid IPv6 configuration Ipv6 address cannot be specified without specifying prefix-length
174 Invalid IPv6 configuration dnssrcv6 cannot be set to auto when ipsrcv6 is set to manual
175 Error while executing IPMI Set command
176 Error while executing IPMI Get command
177 Error during Trap Alert
178 Unspecified error
179 Unsupported device Re-try with supported device
180 Setup password is required Re-try providing setup/admin password
181 System password is required Re-try providing system password
182 The password supplied is incorrect Please try again
183 Password verification failed
184 User input password does not fit system requirement
185 Password not installed in the system
186 password status is disabled
187 Error in Validation
188 Error in Setting the Value
189 SMI call (10-0) only supports password no more than %d characters
190 This is not a Dell machine CCTK supports only Dell machines
191 Setup Password is required to change the setting Use –valsetuppwd to provide password
192 System Password is required to change the setting Use –valsyspwd to provide password
193 Password is not Installed so use only –setuppwd
194 Password is not Installed so use only –syspwd
195 The system password supplied is incorrect Please try again
196 The Sequence list must be a comma-separated list of valid unique device names (ex: hdd,cdrom)
197 The system revision information is not available for this system
198 The completion code information is not available for this system
199 The BIOS characteristics information is not available for this system
200 The password should not contain special characters
201 Please use 64-bit version of this application
202 %s cannot be modified when TPM is OFF
203 System password cannot be set when pwdlock option is in locked state (pwdlock=lock)
204 adddevice option not supported by this machine’s BIOS
205 usb device already present in this machine
206 Unable to get information from BIOS
207 %s – Error : Unable to store BIOS information
208 Duplicate entry found in the input list : %s , Operation Aborted
209 Typo found in the input list : %s , Operation Aborted
210 Asset tag can have only printable ASCII characters
211 Multiple inputs will not be accepted
212 Invalid Hex format
213 Hex value range should be 0x0 to 0xffff
214 %s – Only positive numeric values are acceptable
215 %s – Length cannot exceed two characters
216 Range for autoon hour value should be 0 to 23(24 hour format)
217 Range for autoon minute value should be 0 to 59
218 This Option Not supported on UEFI Bios
219 Unable to Set Bootorder
220 Invalid Arguments Unable to Set Bootorder
221 %s should not combine with other suboptions
222 The property ownership tag for this system is not available
223 The property ownership tag cannot be more than 80 characters for non portable machines
224 The property ownership tag is limited to 48 characters for portable systems
225 Property ownership tag can have only printable ASCII characters
226 Error in Setting the Value\nNote : In some machines, If System password is set, you can’t set Setup password
227 ‘admin/root’ privileges required to execute this application
228 The option related BIOS information is not available in this machine
229 Improper Output from Bios Please try again
230 Error in Bootorder
231 The manufacturing/first-power-on date information is not present on this system
232 Not Applicable
233 Uefi bootlisttype is not supported in this Machine
234 Improper Output from Bios Please try again
235 Error in Bootorder
236 Unable to get information specific to machine
237 The input file is invalid
238 No Status Present
239 File Do not have configurable Options
240 Please provide the days to enable
241 Password is not Installed Please try again without providing –val%s
242 Please provide the old password to set the new password using –valownerpwd
243 The owner password is incorrect Please try again
244 Error in setting the value Note : Setup or system password might be set on the system
245 Owner password is not supported in file operations
246 Password operation is not supported on the system
247 The owner of the system has enabled the Owner Access feature To set the Bios configuration, create setup or system password
248 Either the system hardware or the BIOS version does not support the option To resolve the BIOS version issue, upgrade the BIOS to the latest version
249 Unable to get password information
249 Unable to get password information.